Two clocks and CDC

You will declare clock domains, see why a signal cannot simply cross from one to another, and use sync() and AsyncFifo to cross safely. The chapter also covers resets in a design with several clocks.

Before you start

  • Window: a terminal (how to open one) and your editor.

  • Folder: your volt-projects folder. This chapter makes a new folder there, clocks. Type this:

    cd ~/volt-projects
    
  • Running: for the section Test it, Docker Desktop with Engine running in its window (Setup shows how): volt test runs the Verilator simulator in Docker. If Verilator is installed on your computer, Docker is not needed; volt doctor says which one volt test uses. The other sections need nothing but Volt.

The output on this page was recorded with Volt 0.1.0 in PowerShell on Windows 11, with Docker Desktop running Verilator. On macOS and Linux, paths are written with / instead of \.

Two clocks, two domains

The Tour moved a single bit, a button, from one clock to another. This chapter moves numbers. A sensor chip, here an analog-to-digital converter (ADC), delivers 8-bit samples with a clock of its own; the rest of the design runs on the system clock. Each clock, with the registers it drives, is a clock domain. The samples have to cross from the ADC domain into the system domain.

Make a folder clocks and go into it:

Type this:

mkdir clocks

Type this:

cd clocks

In this folder, create the file sample_bridge.volt (as Setup shows). This version keeps the latest sample in a register of the ADC domain and copies it into a register of the system domain:

Create this file: sample_bridge.volt

// Samples from a sensor clock reach the system clock.

domain Adc {
    clock = posedge
    reset = sync active_high
}

domain Sys {
    clock = posedge
    reset = sync active_high
}

pub module SampleBridge {
    in  adc_clk      : clock @Adc
    in  sys_clk      : clock @Sys
    in  rst          : reset(sync, active_high)
    in  sample       : u8    @Adc
    in  sample_valid : bool  @Adc
    out data         : u8    @Sys

    reg last_r : u8 = 0
    on adc_clk {
        if sample_valid {
            last_r <= sample
        }
    }

    reg data_r : u8 = 0
    on sys_clk {
        data_r <= last_r
    }

    data = data_r
}

What is new compared with the counter:

  • A domain block names a clock domain and says how its registers work. clock = posedge means they update on the rising edge of the clock. reset = sync active_high means their reset is synchronous, read at a clock edge like any other input, and active high: 1 means reset.
  • @Adc after a port type puts the port into the domain Adc. The clock port adc_clk is the clock of that domain.
  • A register belongs to the domain of the on block that writes it: last_r to Adc, data_r to Sys.
  • in rst : reset(sync, active_high) is the reset input of the design. Reset with two clocks below explains why it is written out here, while the counter got its reset without asking.

A design with a single clock needs no domain at all; Volt puts everything into one domain by itself.

This design is wrong on purpose. Check it:

Type this:

volt check sample_bridge.volt

You should see:

    Checking sample_bridge.volt
error[E3001]: direct assignment between clock domains
   ┌─ sample_bridge.volt:30:9
   │
 3 │ domain Adc {
   │        --- source @Adc defined here
   ·
 8 │ domain Sys {
   │        --- destination @Sys defined here
   ·
30 │         data_r <= last_r
   │         ^^^^^^    ------ @Adc
   │         │          
   │         @Sys
   │
   = reason: the destination register may sample the source signal during an unstable window (metastability)
   = note: for multi-bit data, AsyncFifo may be safer
   = help: synchronize at module level, outside this block: let s = sync(<signal>, <clock of Sys>), then read s here
   = for more: volt explain E3001


    Finished 0.01s
      Result 1 error(s), 0 warning(s)

Line 30 reads last_r, a register of Adc, in an on sys_clk block of Sys. That is a clock domain crossing (CDC) without a synchronizer, error E3001. The note line already points to the way out for a number: AsyncFifo. The next section shows why the sync() of the Tour is not enough here.

Why sync() is not enough for a number

sync() builds a two-flop synchronizer for each bit. Do what the help line suggests: synchronize last_r at module level and read the synchronized name in the on sys_clk block. Replace the file:

Replace this file: sample_bridge.volt

// Samples from a sensor clock reach the system clock.

domain Adc {
    clock = posedge
    reset = sync active_high
}

domain Sys {
    clock = posedge
    reset = sync active_high
}

pub module SampleBridge {
    in  adc_clk      : clock @Adc
    in  sys_clk      : clock @Sys
    in  rst          : reset(sync, active_high)
    in  sample       : u8    @Adc
    in  sample_valid : bool  @Adc
    out data         : u8    @Sys

    reg last_r : u8 = 0
    on adc_clk {
        if sample_valid {
            last_r <= sample
        }
    }

    let last_s = sync(last_r, sys_clk)

    reg data_r : u8 = 0
    on sys_clk {
        data_r <= last_s
    }

    data = data_r
}

Type this:

volt check sample_bridge.volt

You should see:

    Checking sample_bridge.volt
warning[W3003]: two-flop synchronization does not guarantee bit coherence for 8-bit signals
   ┌─ sample_bridge.volt:28:18
   │
28 │     let last_s = sync(last_r, sys_clk)
   │                  ^^^^^^^^^^^^^^^^^^^^^ bits may be captured on different edges
   │
   = reason: a two-flop synchronizer synchronizes each bit independently; when bits are captured on different clock edges an invalid intermediate value appears
   = help: for multi-bit data use one of:
                AsyncFifo<T, N>   — data streams
                HandshakeSync<T>  — single transfers
                gray coding       — counters
                AsyncDualPortRam<T, N> — random-access data
   = for more: volt explain W3003


    Finished 0.01s
      Result 0 error(s), 1 warning(s)
       Next: volt build sample_bridge.volt   (emit SystemVerilog)

The design compiles now, with warning W3003: eight synchronizers side by side do not keep the eight bits together.

New to hardware? Why the bits of a number fall apart

Each synchronizer settles on its own. When last_r goes from 127 (0111_1111) to 128 (1000_0000), all eight bits change at once. If the system clock samples during the change, some synchronizers pass the new bit one cycle before the others, and for that cycle the system domain sees a mix of old and new bits: 255, 0, or any other value that last_r never held. A single bit has no such problem: it is either old or new.

It is a warning and not an error because some values survive it: a counter in Gray code changes one bit at a time, and a setting that is written once and read much later has long settled. For a stream of samples, use a FIFO.

A FIFO between the clocks

AsyncFifo is a built-in component: a small memory written on one clock and read on the other, with the synchronizers it needs inside. Every sample goes in on the ADC side and comes out on the system side, in the same order. This version of the design also says when data holds a new sample (data_valid), and when a sample was lost because the FIFO was full (dropped). Replace the file:

Replace this file: sample_bridge.volt

// Samples from a sensor clock reach the system clock.

domain Adc {
    clock = posedge
    reset = sync active_high
}

domain Sys {
    clock = posedge
    reset = sync active_high
}

pub module SampleBridge {
    in  adc_clk      : clock @Adc
    in  sys_clk      : clock @Sys
    in  rst          : reset(sync, active_high)
    in  sample       : u8    @Adc
    in  sample_valid : bool  @Adc
    out data         : u8    @Sys
    out data_valid   : bool  @Sys
    out dropped      : bool  @Adc

    wire take : bool @Sys

    let fifo = AsyncFifo<u8, 4> {
        wr_clk:  adc_clk,
        wr_data: sample,
        wr_en:   sample_valid,
        rd_clk:  sys_clk,
        rd_en:   take,
    }

    take = !fifo.rd_empty

    reg valid_r : bool = false
    on sys_clk {
        valid_r <= take
    }

    data       = fifo.rd_data
    data_valid = valid_r
    dropped    = sample_valid && fifo.wr_full
}

Type this:

volt check sample_bridge.volt

You should see:

    Checking sample_bridge.volt
    Finished 0.01s
      Result 0 error(s), 0 warning(s)
       Next: volt build sample_bridge.volt   (emit SystemVerilog)

How it works:

  • AsyncFifo<u8, 4> holds up to 4 values of type u8. The size must be a power of two.
  • The ports that start with wr_ belong to the domain of wr_clk, here Adc; the ports that start with rd_ belong to the domain of rd_clk, Sys. Volt checks what you connect: sample is @Adc and goes to wr_data. Connecting sample_valid to rd_en would be error E3001 again.
  • fifo.rd_empty is true when there is nothing to read, and fifo.wr_full is true when there is no room. The read side reads whenever the FIFO is not empty: take = !fifo.rd_empty.
  • wire take : bool @Sys declares the wire, with its domain, above the FIFO, because a name must be declared before it is used (error E1002). Its value is given further down. The @Sys is a promise that Volt checks: assigning it a value of Adc would be an error.
  • fifo.rd_data is a register: a value read with rd_en appears on it one clock cycle later. valid_r delays take by the same cycle, so data_valid is true exactly when data holds a new sample.
  • dropped is in the Adc domain, because both of its inputs are.

Coming from SystemVerilog? A dual-clock FIFO without an IP core

In SystemVerilog you would instantiate a vendor FIFO generator or a hand-written FIFO with Gray-coded pointers, and a CDC tool would be told to trust it. AsyncFifo is generated into the module itself: Gray-coded read and write pointers, a two-flop synchronizer for each pointer, and a comment that names the crossing. The compiler knows which side belongs to which domain, so the crossing is checked like any other. Other built-in bridges: HandshakeSync for a single word now and then, PulseSync for a one-cycle pulse, AsyncDualPortRam for a memory (volt explain stdlib).

Reset with two clocks

A reset has to be released in step with the clock of every register it resets. With one clock that is easy. With two, the moment the reset goes away may be right on an edge of one clock while it is far from the edges of the other.

The line in rst : reset(sync, active_high) declares the reset as a raw input: it comes from outside and is in step with neither clock. For a raw reset, Volt builds one reset synchronizer for each clock that it reaches, two flip-flops that pass the release on in step with that clock. Each domain is then reset from its own copy.

Without that line, Volt still adds a reset port named rst, as for the counter, but it cannot know which clock the reset is in step with, and volt check warns:

You should see (if the rst line is missing):


Keep the line. The recipe Reset synchronizers shows the generated synchronizers, asynchronous resets and the related errors.

Test it

Create sample_bridge_test.volt next to sample_bridge.volt:

Create this file: sample_bridge_test.volt

// Simulation tests for SampleBridge. The test bench drives every clock
// of the design together, one edge per step().

test "samples cross in order" {
    let dut = SampleBridge { };
    dut.sample_valid = true;
    dut.sample = 10;
    step(1);
    dut.sample = 20;
    step(1);
    dut.sample = 30;
    step(1);
    dut.sample_valid = false;
    assert_false(dut.data_valid);
    step(1);
    assert_true(dut.data_valid);
    assert_eq(dut.data, 10);
    step(1);
    assert_eq(dut.data, 20);
    step(1);
    assert_eq(dut.data, 30);
    step(1);
    assert_false(dut.data_valid);
}

test "a full FIFO drops samples" {
    let dut = SampleBridge { };
    dut.sample_valid = true;
    step(3);
    assert_false(dut.dropped);
    step(1);
    assert_true(dut.dropped);
}

The test bench drives both clocks together: step(1) gives one rising edge to adc_clk and one to sys_clk. The tests cannot run the two clocks at different speeds, so they do not show the timing problems a synchronizer protects against. What they show is the order of the samples and how long a crossing takes. In the earliest test, the sample 10 is written on edge 1 and is on data after edge 4: the write pointer has to pass a synchronizer before the read side sees it, and the read itself takes a cycle. In the second test a sample arrives on every edge. After four of them the write side sees the FIFO as full, because it learns about the reads through a synchronizer too, and dropped turns on: the next sample would be lost.

Check that Docker Desktop says Engine running, then run the tests:

Type this:

volt test sample_bridge_test.volt

You should see:

   Compiling sample_bridge_test.volt
running 2 tests
note: Verilator not found locally; running it in Docker (verilator/verilator:v5.052)
test samples_cross_in_order ... ok
test a_full_FIFO_drops_samples ... ok

cover summary:
  SampleBridge.fifo_cov_0 (sample_bridge.volt:25)  hit 1 time
  SampleBridge.fifo_cov_1 (sample_bridge.volt:25)  hit 10 times

test result: ok. 2 passed; 0 failed

The cover summary lists two covers that you did not write: AsyncFifo brings them along, which is why both point to line 25, the let fifo line. fifo_cov_0 counts the cycles in which the FIFO was full, fifo_cov_1 those in which it was empty. Both were reached, so the tests drove the FIFO to both of its limits.

The SystemVerilog

Type this:

volt build sample_bridge.volt

You should see:

   Compiling sample_bridge.volt
    Finished 0.01s (1 source file(s), 1 SV file(s))
     Output build\rtl\SampleBridge.sv (127 lines)
       Next: volt run sample_bridge.volt      (simulate)
             volt verify sample_bridge.volt   (prove contracts)

build/rtl/SampleBridge.sv holds one module, with the FIFO and the reset synchronizers inside. These comment lines in it name each part (output trimmed):

You should see:

    // reset synchronizer: rst -> adc_clk (async assert, sync release)
    // reset synchronizer: rst -> sys_clk (async assert, sync release)
    // AsyncFifo 'fifo': adc_clk -> sys_clk, depth 4 (gray-code pointers)

You are in the clocks folder.

What we learned

  • A domain names a clock domain; @Name puts a port or a wire into it, and a register belongs to the domain of its on block.
  • Reading a signal of one domain in another is error E3001.
  • sync() is for a single bit. On a number it is warning W3003, because the bits can arrive in different cycles.
  • AsyncFifo carries a stream of values between two clocks; its wr_ and rd_ ports belong to the two domains.
  • A raw reset port, in rst : reset(...), gets one reset synchronizer per clock.
  • volt test drives every clock together, one edge per step().

Next: contracts and formal verification prove properties of a design for every input, not just the ones a test tries.