A clock domain crossing error

In this chapter you will write a design with two clocks, pass a signal from one to the other the wrong way, and read the error Volt reports. Then you will fix it with sync() and see what the fix becomes in SystemVerilog.

Before you start

  • Window: a terminal (how to open one) and your editor.

  • Folder: your volt-projects folder. This chapter makes a new folder there, cdc, next to blinky. Type this:

    cd ~/volt-projects
    
  • Running: nothing else. This page does not need Docker.

The output on this page was recorded with Volt 0.1.0 in PowerShell on Windows 11.

Two clocks

Real designs often have more than one clock: a fast one for the core, a slower one for a peripheral. Each clock, with the registers it drives, is a clock domain.

This design is a single file, not a project, so it gets a folder of its own. Make the folder cdc and go into it:

Type this:

mkdir cdc

Type this:

cd cdc

In this folder, create the file crossing.volt (with the clipboard command, VS Code or Notepad, as Setup shows). A button is sampled by the fast clock; a LED is driven by the slow clock:

Create this file: crossing.volt

// A button sampled in one clock domain drives a LED in another.

domain Fast {
    clock = posedge
    reset = sync active_high
}

domain Slow {
    clock = posedge
    reset = sync active_high
}

pub module Crossing {
    in  fast_clk : clock @Fast
    in  slow_clk : clock @Slow
    in  rst      : reset(sync, active_high)
    in  button   : bool  @Fast
    out led      : bool  @Slow

    reg pressed_r : bool = false
    on fast_clk {
        pressed_r <= button
    }

    reg led_r : bool = false
    on slow_clk {
        led_r <= pressed_r
    }

    led = led_r
}

The two domain blocks name the clock domains. @Fast and @Slow put each port into one of them. The reset rst is shared: Volt synchronizes it to each clock by itself. The register pressed_r belongs to Fast, because on fast_clk updates it; led_r belongs to Slow.

This design is wrong on purpose. Check it. Because the folder has no Volt.toml, the command names the file:

Type this:

volt check crossing.volt

You should see:

    Checking crossing.volt
error[E3001]: direct assignment between clock domains
   ┌─ crossing.volt:27:9
   │
 3 │ domain Fast {
   │        ---- source @Fast defined here
   ·
 8 │ domain Slow {
   │        ---- destination @Slow defined here
   ·
27 │         led_r <= pressed_r
   │         ^^^^^    --------- @Fast
   │         │         
   │         @Slow
   │
   = reason: the destination register may sample the source signal during an unstable window (metastability)
   = note: for multi-bit data, AsyncFifo may be safer
   = help: sync() is written at module level: add 'let pressed_r_sync = sync(pressed_r, slow_clk)' above this block and read the synchronized name here
   = for more: volt explain E3001


    Finished 0.00s
      Result 1 error(s), 0 warning(s)

The error says which line crosses (27), where each domain comes from (lines 3 and 8), why this is a problem and how to fix it. volt explain E3001 prints a longer explanation. The command exits with code 1, and volt build would write no SystemVerilog.

New to hardware? Why a crossing needs a synchronizer

A flip-flop samples its input at the clock edge. If the input changes right at that moment, the flip-flop can hang between 0 and 1 for a while before it settles; this is called metastability. Two clocks that are not related drift against each other, so sooner or later a change lands right on an edge. A synchronizer, two flip-flops in a row on the receiving clock, gives the front one a full clock period to settle before anyone reads the value. The bug is rare and random, which is why it is hard to find in the lab and why Volt rejects it at compile time.

The fix

sync() builds the synchronizer. Do what the help line says: add the line let pressed_r_sync = sync(pressed_r, slow_clk) above the on slow_clk block, which brings pressed_r into the Slow domain, and read pressed_r_sync instead of pressed_r under slow_clk. The name pressed_r_sync is the one the help line suggests; any free name works, as long as both lines use the same one.

Replace this file: crossing.volt

// A button sampled in one clock domain drives a LED in another.

domain Fast {
    clock = posedge
    reset = sync active_high
}

domain Slow {
    clock = posedge
    reset = sync active_high
}

pub module Crossing {
    in  fast_clk : clock @Fast
    in  slow_clk : clock @Slow
    in  rst      : reset(sync, active_high)
    in  button   : bool  @Fast
    out led      : bool  @Slow

    reg pressed_r : bool = false
    on fast_clk {
        pressed_r <= button
    }

    let pressed_r_sync = sync(pressed_r, slow_clk)

    reg led_r : bool = false
    on slow_clk {
        led_r <= pressed_r_sync
    }

    led = led_r
}

sync() goes on a line of its own at module level; inside an on block it is not supported yet, which is why the help line puts it above the block. Check again:

Type this:

volt check crossing.volt

You should see:

    Checking crossing.volt
    Finished 0.00s
      Result 0 error(s), 0 warning(s)
       Next: volt build crossing.volt   (emit SystemVerilog)

Now write the SystemVerilog:

Type this:

volt build crossing.volt

You should see:

   Compiling crossing.volt
    Finished 0.00s (1 source file(s), 1 SV file(s))
     Output build\rtl\Crossing.sv (86 lines)
       Next: volt run crossing.volt      (simulate)
             volt verify crossing.volt   (prove contracts)

Open build/rtl/Crossing.sv (in the cdc folder) in your editor. The sync() line became two flip-flops on slow_clk. This is a part of the file (output trimmed):

You should see:

    // CDC synchronizer: pressed_r -> slow_clk
    logic sync_pressed_r_stage0;
    logic sync_pressed_r_stage1;

    always_ff @(posedge slow_clk) begin
        if (rst_sync_slow_clk_stage1) begin
            sync_pressed_r_stage0 <= 1'b0;
            sync_pressed_r_stage1 <= 1'b0;
        end else begin
            sync_pressed_r_stage0 <= pressed_r;
            sync_pressed_r_stage1 <= sync_pressed_r_stage0;
        end
    end

    assign pressed_r_sync = sync_pressed_r_stage1;

The file also holds one reset synchronizer per clock (rst_sync_fast_clk_stage1, rst_sync_slow_clk_stage1): the shared rst is asserted at once but released in step with each clock. Their always_ff blocks react to rst directly (or posedge rst) although both domains say reset = sync. This is on purpose: the reset takes effect even while a clock is stopped, and its release is still aligned to each clock, so every register of a domain sees a synchronous reset and leaves it on the same clock edge.

You are in the cdc folder. The next chapter goes back to blinky.

Coming from SystemVerilog? The same bug compiles there

always_ff @(posedge slow_clk)
    led_r <= pressed_r;   // pressed_r is clocked by fast_clk

SystemVerilog accepts this without a warning; a CDC tool or a review has to catch it later. In Volt every signal carries its clock domain in its type, the way a Rust value carries its type, so a crossing is a type error. sync() is a compiler primitive, not a library module, so the compiler knows the crossing is safe. It is meant for one bit; a multi-bit sync() is a warning (W3003), and words cross through the built-in AsyncFifo. A synchronizer you write by hand out of two registers is not recognized.

Next: tests and waveforms.